Fitting for the solar lighting system is automatically controlled below 3A (12V) for both lighting and solar panel.
I Function:
Prevent battery from over charging, over discharging and reverse-current during nights.
II Connection (See the drawing below):
1. Please make sure according to the following step order.
2. Connect the “+”, “-” Poles of the battery to the relevant terminal of the controller firmly and correctly.
3. Connect the “+”, “-” Poles of the solar panel to the relevant terminal of the controller firmly and correctly.
4. Connect the “+”, “-” Poles of the load to the relevant terminal of the controller firmly and correctly.
Attention Items:
1. before connection, please check and confirm the rated voltage of the solar panels, batteries and the loads carefully. These must be same rated voltage, all 12V.
2. The rated current of the solar panels and the load must be less than the rated current of the controller (3A).
3. The load of the controller can not be short-circuiting.
4. It should not charge up the battery by other powers instead of solar panels according to controller.
The Parameter Sheet:
|
Rated Voltage |
12V |
Voltage of stop power supply |
* 10.8V |
|
Rated charging current |
3A |
Voltage of resume power supply |
* 12.6V |
|
Rated load current |
3A |
Voltage of stop charge |
* 14.4V |
|
Working temperature |
-20 ~ +40℃ |
Temperature Coefficient of Voltage stop charge |
-3mV/℃/cell |
|
Light controlling enactment |
30M |
Relative humidity |
≤90% |
|
Size (Length*Width*Height) |
55*36*20mm |
Net Weight |
33g |
Copyright 2012 by Aushop.Net. All Rights reserved.